產(chǎn)品內(nèi)容介紹
XYCOM 9487-47B1319210000連接控制終端
4.02版驅(qū)動(dòng)器AOP需要用戶操作才能啟用ADC。這有助于驗(yàn)證用戶在打開(kāi)ADC之前了解ADC操作。請(qǐng)注意使用4.02版(或更高版本)驅(qū)動(dòng)器AOP時(shí),ADC工作狀態(tài)如下:
?添加新驅(qū)動(dòng)器時(shí),對(duì)于任何支持ADC,例如固件為7.001或更高版本的PowerFlex 753驅(qū)動(dòng)器,或固件為4.001或更高版本的PowerFlex 755驅(qū)動(dòng)器。
?將早期的RSLogix 5000項(xiàng)目轉(zhuǎn)換為版本20.00時(shí)已使用4.02(或更高版本)Drive AOP或更新使用4.01版驅(qū)動(dòng)器AOP創(chuàng)建的項(xiàng)目時(shí),任何ADC對(duì)于支持ADC的驅(qū)動(dòng)器,設(shè)置將按原樣傳遞。對(duì)于例子:
–如果在以前的項(xiàng)目中對(duì)某個(gè)驅(qū)動(dòng)器禁用了ADC,它將保留殘廢
–如果使用4.01版驅(qū)動(dòng)器AOP的驅(qū)動(dòng)器啟用了ADC,并且項(xiàng)目后來(lái)更新到4.02(或更高版本)Drive AOP,它將保持啟用狀態(tài)。
通過(guò)相應(yīng)的端口屬性對(duì)話框管理外圍設(shè)備的鍵控每個(gè)外圍設(shè)備的框。
嵌入式EtherNet/IP適配器的電子鍵控(僅端口13PowerFlex 755驅(qū)動(dòng)器上)和DeviceLogix(端口14)端口被“禁用”默認(rèn)情況下。
兩個(gè)端口都沒(méi)有單獨(dú)的固件,目前由驅(qū)動(dòng)器固件(端口0)管理。如果將其中之一設(shè)置為“完全匹配”,固件主管將無(wú)法找到升級(jí)安裝過(guò)程中的文件。如果“外圍設(shè)備驅(qū)動(dòng)連接故障”復(fù)選框被選中,并且在連接到時(shí)出現(xiàn)不匹配或故障或者配置這兩個(gè)端口,整個(gè)ADC進(jìn)程將失敗將與驅(qū)動(dòng)器進(jìn)行I/O連接。
HIM和串行轉(zhuǎn)換器(1203-SSS和1203)的電子鑰匙-USB)默認(rèn)禁用。
這些通常是臨時(shí)設(shè)備或僅用于監(jiān)控目的,因此,如果是否存在。
您仍然可以選擇將這些設(shè)置為其他鍵控選擇(如果需要)。兼容模塊此選擇是不使用固件管理器時(shí)的典型ADC選擇。
A.更換驅(qū)動(dòng)器(包括外圍設(shè)備)需要具有相同或更高的固件版本與原始版本相同。由于需要更新固件的驅(qū)動(dòng)器與舊固件兼容,這允許ADC在不兼容的情況下工作關(guān)注點(diǎn)。請(qǐng)注意,如果系列更改伴隨著主要固件更改,則替換驅(qū)動(dòng)器可能與鍵控“兼容”,也可能不兼容。
禁用使用ADC時(shí),通常不應(yīng)使用此選項(xiàng)。此選擇允許更換驅(qū)動(dòng)器以具有任何不同的主(X.xxx)和/或次(X.xx)固件修訂由用戶提供具有固件版本的更換件晚于或等于原始驅(qū)動(dòng)器。如果更換驅(qū)動(dòng)器的固件較舊則ADC下載可能失敗。
Version 4.02 Drive AOPs require user action to enable ADC.
This helps verify that the user understands ADC operation prior to turning it on. Note the following ADC operating status when using version 4.02 (or later) Drive AOPs: ? When adding a new drive, ADC is disabled by default for any drive that supports ADC, such as PowerFlex 753 drives with firmware 7.001 or later, or PowerFlex 755 drives with firmware 4.001 or later. ? When converting an earlier RSLogix 5000 project to a version 20.00 project that has been updated with version 4.02 (or later) Drive AOPs or when updating a project created with version 4.01 Drive AOPs, any ADC settings will be passed through as-is for drives that support ADC. For example: – If ADC was disabled for a drive in a previous project, it will remain disabled. – If ADC was enabled for a drive using version 4.01 Drive AOPs and that project was later updated to version 4.02 (or later) Drive AOPs, it will remain enabled.Keying for peripherals is managed via the respective Port Properties dialog box for each peripheral.
Electronic Keying for the embedded
EtherNet/IP adapter (only Port 13 on PowerFlex 755 drives) and DeviceLogix (Port 14) ports are “Disabled” by default. Both ports do not have individual firmware and are currently managed by the drive’s firmware (Port 0). If you set either of these to “Exact Match,” Firmware Supervisor will be unable to locate the upgrade files during setup. If the “Fault Drive Connection on Peripheral Error” checkbox is selected and there is a mismatch or failure while connecting to or configuring these two ports, the overall ADC process will fail and no I/O connection will be made to the drive. Electronic Keying for HIMs and serial converters (1203-SSS and 1203- USB) are disabled by default. These are typically temporary devices or used for monitoring purposes only and therefore “do not matter” if they are present or not. You still have the option to select these to other Keying selections if desired.
Compatible Module
This selection is the typical ADC selection when Firmware Supervisor is not used. A replacement drive (including peripherals) will need to have the same or higher firmware revision as the original. Since drives with newer firmware are required to be compatible with older firmware, this allows ADC to work without compatibility concerns. Note that if a Series change accompanies a Major firmware change, the replacement drive may or may not be “compatible” with respect to keying. Disabled When using ADC, this selection should generally not be used. This selection allows a replacement drive to have any different Major (X.xxx) and/or Minor (X.xxx) firmware revision. It is up to the user to provide a replacement that has a firmware revision later than or equal to the original drive. If a replacement drive with older firmware is used, the ADC download may fail.
公司主營(yíng)產(chǎn)品圖展示
產(chǎn)品優(yōu)勢(shì)
1:國(guó)外專業(yè)的供貨渠道,具有價(jià)格優(yōu)勢(shì)
2:產(chǎn)品質(zhì)量保證,讓您售后無(wú)憂
3:全國(guó)快遞包郵
4:一對(duì)一服務(wù)
公司主營(yíng)范圍簡(jiǎn)介
PLC可編程控制器模塊,DCS卡件,ESD系統(tǒng)卡件,振動(dòng)監(jiān)測(cè)系統(tǒng)卡件,汽輪機(jī)控制系統(tǒng)模塊,燃?xì)獍l(fā)電機(jī)備件等,優(yōu)勢(shì)品牌:Allen Bradley、BentlyNevada、ABB、Emerson Ovation、Honeywell DCS、Rockwell ICS Triplex、FOXBORO、Schneider PLC、GE Fanuc、Motorola、HIMA、TRICONEX、Prosoft等各種進(jìn)口工業(yè)零部件、歐美進(jìn)口模塊。
產(chǎn)品廣泛應(yīng)用于冶金、石油天然氣、玻璃制造業(yè)、鋁業(yè)、石油化工、煤礦、造紙印刷、紡織印染、機(jī)械、電子制造、汽車制造、塑膠機(jī)械、電力、水利、水處理/環(huán)保、鍋爐供暖、能源、輸配電等等