UFC911B110控制卡件,UFC911B110使用手冊(cè)
特色功能:OS Recovery
具備源控系列產(chǎn)品共有的OS Recovery硬件級(jí)別系統(tǒng)還原功能,在由斷電、軟件不兼容等情況導(dǎo)致的系統(tǒng)崩潰情況下只需一按,即可實(shí)現(xiàn)系統(tǒng)一鍵還原,解決了重裝系統(tǒng)難度大、等待售后服務(wù)成本高等問(wèn)題。
目前,蘇州源控的工業(yè)計(jì)算機(jī)產(chǎn)品已廣泛應(yīng)用于AGV、智能倉(cāng)儲(chǔ)、智慧農(nóng)業(yè)、工業(yè)自動(dòng)化、MES等領(lǐng)域。隨著應(yīng)用場(chǎng)景的不斷豐富,源控也將持續(xù)投入產(chǎn)品研發(fā),為智慧產(chǎn)業(yè)升級(jí)注入強(qiáng)勁動(dòng)力。當(dāng)高溫顯示器遇上低溫冷水
UFC911B110控制卡件ifm顯示器其中一個(gè)應(yīng)用場(chǎng)景便是在地下礦井,那里不僅溫度高,還會(huì)有從密封處流出的冷水?,F(xiàn)在,我們就模擬這個(gè)場(chǎng)景,看是否會(huì)對(duì)顯示器造成影響。
我們用一個(gè)經(jīng)典的泛光燈來(lái)對(duì)ifm顯示器進(jìn)行加熱,直至74.2℃,也準(zhǔn)備了一些1.9℃的冷水。將冷水澆到高溫的顯示器后,可以看到顯示器沒(méi)有開(kāi)裂,仍能正常工作!
當(dāng)顯示器遭遇物體高空墜落
ifm這款顯示器屏幕的玻璃厚度為2.8mm,我們將一個(gè)0.5kg重的砝碼從1m高的位置落下,并且又用該砝碼重?fù)羲ご蝻@示器。經(jīng)過(guò)高空重物墜落及摔打的嚴(yán)苛測(cè)試后,顯示器仍完好無(wú)損,極度堅(jiān)固,正常工作。
當(dāng)顯示器被冷凍結(jié)霜
我們分別進(jìn)行了12"顯示器和7"顯示器的測(cè)試,依次將它們從-17℃的冰箱中拿出,通上電后,刮擦屏幕可以看到上面有一些結(jié)霜,繼續(xù)觸控屏幕,操作完全沒(méi)問(wèn)題!
即便身處地下采礦環(huán)境
仍發(fā)揮強(qiáng)大功能
Boart Longyear一直是全球鉆探行業(yè)產(chǎn)品與服務(wù)的領(lǐng)導(dǎo)者。
視頻中的機(jī)器是適用于戶外應(yīng)用的表面鉆機(jī),可以看到,其中應(yīng)用了許多ifm傳感器,包括最新版本的溫度傳感器、電感式接近開(kāi)關(guān)、壓力傳感器和動(dòng)態(tài)傾角傳感器,所有這些產(chǎn)品都通過(guò)ifm適用于移動(dòng)機(jī)械的控制系統(tǒng)關(guān)聯(lián)在一起。
該控制系統(tǒng)中使用了最新一代的CR721S控制器和CR1203顯示器。由于CR721S是一種安全控制器,可以將標(biāo)準(zhǔn)機(jī)器功能和安全功能集于一身,非常實(shí)用。
set the communication rates of un300 and un200 to be consistent, which can be set to 9.6K, 19.2k and 187.5k baud rates. Then set the sfc67 and sfc68 function blocks.
2. PROFIBUS DP communication
This is the communication mode with the best stability and real-time performance, but EM277 should be added to un200 in hardware. This method is also the simplest in software. As long as the GSD file of 277 is added to STEP7 and set in hardware configuration.
For PROFIBUS DP communication between un300 and un200 through EM277, it is necessary to configure the un300 station in STEP7. There is no need to configure and program the communication in the un200 system. It is only necessary to sort out and store the data to be communicated in the V storage area, which corresponds to the hardware I / O address of the EM277 slave station of un300 configuration.
Insert a un300 station, and then import the GSD file. After importing the GSD file, find the EM277 slave station, PROFIBUS DP → additional field devices → PLC → unimat → UN 277 PROFIBUS-DP, in the device selection list on the right, and select a communication mode according to your number of communication bytes.
After downloading the hardware of un300, turn the position switch of EM277 to be consistent