UNS 0121A-Z,V1勵(lì)磁調(diào)節(jié)器,UNS 0121A-Z,V1使用進(jìn)展
最大負(fù)載/當(dāng)前偏移
對(duì)于連接到腹板張力電子裝置PFEA111/112的每個(gè)稱重傳感器,最大負(fù)載范圍為±6.5 x Fnom的存儲(chǔ)器將存儲(chǔ)施加到稱重傳感器上的最高負(fù)載。最大載荷包括:
?稱重傳感器零信號(hào)(稱重傳感器無(wú)負(fù)載)
?FRT,稱重傳感器測(cè)量方向上皮重的作用力分量
?FR,測(cè)得的力(測(cè)量方向上的張力力分量稱重傳感器)。如果更換稱重傳感器,可以重置最大負(fù)載記憶。
3.12.9.2重置A/B重置A將“MaximumLoad A”設(shè)置為零。重置B將“最大負(fù)載B”設(shè)置為零。
3.12.9.3仿真功能模擬可以設(shè)置為打開或關(guān)閉。

UNS 0121A-Z,V1勵(lì)磁調(diào)節(jié)器如果simulation設(shè)置為ON,則參數(shù)PercentofNoma和PercentofNomb將為顯示。如果在ObjectType和中選擇了單面A,則不會(huì)顯示PercentofNomb如果在ObjectType中選擇了單面B,則不會(huì)顯示PercentofNoma。參數(shù)PercentOfFnom可以一步一步地設(shè)置在–100和+200之間。什么時(shí)候simulation設(shè)置為ON,它將替換稱重傳感器的測(cè)量值。值+100表示該值與加載到Fnom的稱重傳感器相同。
激活模擬時(shí)不能使用零集。當(dāng)模擬設(shè)置為ON時(shí),紅色狀態(tài)led點(diǎn)亮,顯示屏上顯示消息“Simulation”(模擬)。如果按下“ok”(確定),則消息以與故障和警告相同的方式移動(dòng)到操作員菜單的底部信息。
SetFactory Default將模擬設(shè)置為關(guān)閉。將“模擬”設(shè)置為“開”時(shí),默認(rèn)值為:–正常百分比=55%
–PercentOfFnomB=45%“服務(wù)”菜單具有只能查看的參數(shù)和可以設(shè)置的參數(shù)。
UNS 0121A-Z,V1勵(lì)磁調(diào)節(jié)器?只能查看的參數(shù):–軟件版本號(hào)–最大負(fù)載A
顯示自上次重置以來(lái)的最大負(fù)載–當(dāng)前偏移量A
顯示上次零點(diǎn)設(shè)置時(shí)的零點(diǎn)偏移–最大負(fù)載B顯示自上次重置以來(lái)的最大負(fù)載–當(dāng)前偏移量B
顯示上次零點(diǎn)設(shè)置時(shí)的零點(diǎn)偏移?可設(shè)置的參數(shù):–重置A此操作將“最大負(fù)載A”設(shè)置為零。–重置B此操作將“最大負(fù)載B”設(shè)置為零。
–模擬激活/停用模擬功能。
Maximum Load / Present Offset
For each load cell connected to the web tension electronics PFEA111/112, a maximum load
memory, with the range ±6.5 x Fnom, will store the highest load that is applied to the load cell.
The maximum load consists of:
? Load cell zero signal (with no load on the load cell)
? F
RT, applied force component of tare in the measuring direction of the load cell
and
? F
R, measured force (force component of tension in the measuring direction of
the load cell).
The maximum load memory can be reset if a load cell is replaced.
3.12.9.2 Reset A/B
Reset A sets “MaximumLoad A” to zero.
Reset B sets “MaximumLoad B” to zero.
3.12.9.3 Simulation function
Simulation can be set to ON or OFF.
If simulation is set to ON, the parameters PercentOfFnomA and PercentOfFnomB will be
displayed. PercentOfFnomB is not shown if Single side A has been selected in ObjectType and
PercentOfFnomA is not shown if Single side B has been selected in ObjectType.
The parameter PercentOfFnom can be set between –100 and +200 in steps of one. When
simulation is set to ON, it replaces the measured value from the load cells. The value +100
means that the value is the same as load cell loaded to Fnom.
Zero set can not be used when simulation is activated. When simulation is set to ON, the red
status led is lit and on the display the message “Simulation” is shown. If “ok” is pressed, the
message is moved to the bottom of the Operator menu in the same way as failure and warning
messages.
SetFactory Default sets the simulation to OFF.
When simulation is set to ON, the default values are:
– PercentOfFnomA = 55%
– PercentOfFnomB = 45%